home *** CD-ROM | disk | FTP | other *** search
/ PC Advisor 1996 August / PC Advisor August 1996.iso / scanner / scanner.tx_ / scanner.tx
Text File  |  1996-05-11  |  14KB  |  365 lines

  1.  
  2. KNOWLEDGE SOLUTIONS LTD
  3.  
  4. If you require any additional information regarding SCANNER
  5. or need to place an order then please do not hesitate 
  6. to Call our UK Sales Office +44 (0) 181 566-9106 or E-Mail 
  7. Sales@netbureau.com or Fax +44 (0) 181 991-2653 or sign-on
  8. to our on-line service: +44 (0) 181 566-9118 (8/N/1) or Post
  9. your enquires or orders to the address below.
  10.  
  11. CHEQUE, VISA and ACCESS excepted.
  12.  
  13.  KNOWLEDGE SOLUTIONS LTD, RESEARCH HOUSE, FRASER ROAD, 
  14.  PERIVALE, MIDDX, UB6 7AQ, ENGLAND.
  15. -------------------------------------------------------------------
  16.  
  17.  
  18. ** BRIEF OVERVIEW:
  19.  
  20. There are two programs included in this evaluation
  21. (SCHEDULE.EXE & SCANNER.EXE).
  22.  
  23. 1. SCHEDULE: this program initiates any executable program at regular 
  24.    time intervals, or set times during the day (see SCHEDULE.TXT for).
  25.    installation instructions).
  26.  
  27. 2. SCANNER: this scans a directory for a specific file at specified 
  28.    intervals (in seconds), and then notifies you when the file is
  29.    found (See below).
  30.  
  31.  
  32. ** SCANNER background information:
  33.  
  34. SCANNER is a Windows background task program which scans a
  35. directory at given intervals, in seconds, for a specified file. If
  36. the specified file is found it is renamed, and then a customised
  37. message is displayed on the screen, also giving you the file name,
  38. size, and the time and date the file was delivered. SCANNER is very
  39. useful in the on-line world, networking environments and has many other
  40. uses where files are delivered or created automatically.
  41.  
  42.  
  43. *********************************
  44. ** SCANNER Evaluation Features:**
  45.  
  46. 1. The SCANNER background task window displays default header
  47.    information only.
  48.  
  49. 2. Set the SCAN directory and Filename (wildcards supported) that
  50.    SCANNER looks for, using the default .INI file, allowing only one
  51.    SCANNER background task to be run. It is possible to run several
  52.    SCANNER tasks, but they are all reading the same .INI file and will
  53.    be checking the same information. The full version allows you to
  54.    specify multiple .INI files for multiple scanning tasks.
  55.  
  56. 3. Set SCANNER to scan at regular intervals in seconds format,
  57.    using the default .INI file.
  58.  
  59. 4. Customise the pop-up message on detection of specified file,
  60.    using the default .INI file.
  61.  
  62. 5. Specify whether to include the time, date, filename and size in
  63.    the pop-up message, using the default .INI file.
  64.  
  65. 6. Specify whether to record transactions to a log file of your
  66.    choice including name and path, using the default .INI file.
  67.  
  68. 7. You can rename the file using two options types, the first type
  69.    allows you to rename the file to another file name, and the second
  70.    type lets you rename the file to the current date, plus a sequence
  71.    number to the total amount of times files have been found since the
  72.    program has been running.
  73.  
  74. ***********************************
  75. ** SCANNER Full Version Features:**
  76.  
  77. 1. The SCANNER background task window displays any information
  78.    header you want. This can be set before installation so that you
  79.    can supply the SCANNER program to your customers, with your company
  80.    details. If required you or your customer can then change the header
  81.    information to what they wish.
  82.  
  83. 2. Support for Multiple Scanning tasks using any specified .INI
  84.    file, SCAN directories and Filenames (wildcards supported) for each
  85.    SCANNER task being run.
  86.  
  87. 3. Set SCANNER to scan at regular intervals in minute format,
  88.    using any specified .INI file you want, for multiple tasks.
  89.  
  90. 4. Customise the pop-up message on detection of specified file,
  91.    using any specified .INI file you want, for multiple tasks.
  92.  
  93. 5. Specify whether to include the time, date, filename and size in
  94.    the pop-up message, using any specified .INI file you want, for
  95.    multiple tasks.
  96.  
  97. 6. Specify whether to record transactions to a log file of your
  98.    choice including name and path, using any specified .INI file you
  99.    want, for multiple tasks.
  100.  
  101. 7. You can rename the file using two options types, the first type
  102.    allows you to rename the file to another file name, and the second
  103.    type lets you rename the file to the current date, plus add a 
  104.    sequence number to the total amount of times files have been found
  105.    since SCANNER was loaded.
  106.  
  107. 8. Using a line parameter when the SCANNER program is loaded (e.g /R),
  108.    you can tell SCANNER to unload itself when one file has been found.
  109.  
  110. 10. User friendly interface program which allows easy editing of
  111.     the .INI files from Windows, accessed through an icon.
  112.  
  113. 11. Skips already open files.
  114.  
  115. 12. Technical Support and license agreement (special site prices
  116.     for sysops and companies).
  117.  
  118. 13. For site licenses, we can compile the program so that at time of
  119.     installation your company or individual details are specified in 
  120.     the header information, plus you can specify what default .INI
  121.     file parameters should be used.
  122.  
  123.  
  124. ** How can SCANNER be applied?
  125.  
  126. 1. Auto detection when downloading and uploading mail messages
  127.    automatically from an on-line service (See SCHEDULE.TXT).
  128.  
  129. 2. Auto detection when downloading and uploading any files
  130.    automatically (See SCHEDULE.TXT).
  131.  
  132. 3. Auto detection when using the low cost Internet mail gateway
  133.    solution (See SCHEDULE.TXT).
  134.  
  135. 4. Auto detection when a file is created by an event such as an error log 
  136.    file or any other event which causes a file to be created.
  137.  
  138. 5. Let your imagination run free for a little while, SCANNER is very 
  139.    flexible specially when used in conjuction with the SCHEDULE program.
  140.  
  141.  
  142. ** PURCHASE INFORMATION:
  143.  
  144.    APPLICATION FORM SUPPLIED WITHIN THIS EVALUATION PACK! (APP-FORM.TXT)
  145.  
  146. 1. CALL THE SUPPLIED NUMBER AND SPEAK TO A SALES REPRESENTIVE.
  147. 2. FAX YOUR CREDIT CARD ORDERS TO THE SUPPLIED NUMBER.
  148. 2. EMAIL YOUR CREDIT CARD ORDERS TO sales@netbureau.com
  149. 3. SEND YOUR ORDER/CHEQUES VIA POST TO THE ADDRESS SUPPLIED.
  150. 4. LOGON TO OUR ON-LINE SERVICE AND PLACE AN ORDER BY CREDIT CARD.
  151.  
  152.  SYSOP-VERSION: YOU CAN SUPPLY TO ALL YOUR CUSTOMERS.
  153.   SITE-VERSION: THIS ALLOWS UNLIMITED COMPANY SITE USE. 
  154. GLOBAL-VERSION: UNLIMITED COMPANY USE TO AS MANY SITES AS YOU LIKE.
  155.  
  156. ú=POUND STERLING
  157. $=US DOLLAR
  158.  
  159. LICENSE DESCRIPTION             SCHEDULER-PRICE         SCANNER-PRICE   
  160. ---------------------------------------------------------------------------
  161.  
  162. SINGLE USER VERSION:            $18.00 / ú12.00         $18.00 / ú12.00
  163.       SYSOP-VERSION:            $77.00 / ú49.00         $77.00 / ú49.00
  164.        SITE-VERSION:            $93.00 / ú65.00         $93.00 / ú65.00
  165.      GLOBAL-VERSION:            $147.00/ ú95.00         $147.00/ ú95.00
  166.  
  167. ***************************************************************************
  168.  
  169. ** Parameters held in ".INI" file,
  170.  
  171.    (see below for parameters used in the default .INI file supplied at time
  172.     of installation. Sysops and companies can specify the default parameters
  173.     at time of purchase).
  174.  
  175. Header(1,2,3)   - Header information to be displayed in the task window. 
  176.           Each line uses "Times New Roman" with a point size of 18.
  177.           The first line will be displated in red, the rest in
  178.           black. (Full featured version only)
  179.  
  180. ScanTime=       - indicates how many seconds between scans.
  181.  
  182. Path=           - directory in which to scan for files.
  183.         
  184. File=           - file to scan for (wildcards allowed, i.e.
  185.           packet.*).
  186.  
  187. Message=        - text which is displayed in the notify message box
  188.           when a file is found.
  189.  
  190. IncludeTime=    - whether to include the time in the notify message,
  191.           of when the file was found.
  192.  
  193. IncludeDate=    - whether to include the date in the notify message, 
  194.           of when the file was found.
  195.  
  196. IncludeFileName=    - whether to include the new file name in the
  197.               notify message, of the file that was found.
  198.  
  199. IncludeFileSize=    - whether to include file size in the notify message, 
  200.               of the file found.
  201.  
  202. LogPath=       - path and name of the log file.
  203.  
  204. RenameType=    - controls the format the file should be
  205.          renamed to. A value of "1" will rename the file
  206.          to the name given by the "NewName=" parameter (see
  207.          below). A value of "2" will rename the file the following
  208.          format, dd-mm.<ext>. The <ext>  is a sequential number 
  209.          controlled by the "RenameExt" parameter (see below). An
  210.          example: "05-02.Q01"
  211.  
  212. NewName=       - file name to be used for renames when "RenameType=1" is 
  213.          used.
  214.  
  215. RenameExt=     - wildcard style file extension to be used for renames when
  216.          "RenameType=2" is used. trailing "?"s are used as 
  217.          place-holders for sequential numbers within a given day.
  218.          For example, "Q??" will allow files "Q01" through to "Q99" 
  219.          to be created.
  220.  
  221.  
  222. ** SCANNER.INI file is placed in the installation directory.
  223.  
  224. [SCAN]
  225. HEADER1=SCANNER V2.0A                   
  226. HEADER2=personal or company details.    
  227. HEADER3=~you choose the header text~    
  228. ScanTime= 60
  229. ScanPath=C:\DOS
  230. ScanMask=FILENAME.*
  231. Message=This can be any message you like!
  232. IncludeTime=Y
  233. IncludeDate=Y
  234. IncludeFileName=Y
  235. IncludeFileSize=Y
  236. LogPath=C:\DOS\DELIVERY.LOG
  237. RenameType= 2
  238. NewName=NewName.Ext
  239. RenameExt=Q??
  240.  
  241.  
  242. ** Command Line switches for Full Version (the evaluation copy has no
  243.    line switches available).
  244.  
  245. SCAN /R   - This tells the SCANNER program to stop running in the
  246.         background after one initiation attempt has been made.
  247.  
  248. SCAN /I=IniFileName - Where IniFileName should be the name of the .INI file
  249.               you wish to use to setup the SCANNERS's working 
  250.               enviroment, allowing multiple SCANNER tasks.
  251.  
  252.  
  253. ** WINDOWS 3.x SETUP Instructions! 
  254.  
  255. 1. From program manager, select the run option through the File-
  256.    Menu.
  257.  
  258. 2. In the command line: type <drive>:<path>setup.exe. <drive> should be 
  259.    replaced with the hard disk or floppy drive letter the files are stored 
  260.    on. <path> should be replaced with full path to the directory containing 
  261.    the files. For example (Command Line: a:\setup.exe). select OK or press 
  262.    the RETURN key once done, to continue.
  263.  
  264. 3. Set-up will display "Initialising set-up" for a while, then you will
  265.    be prompted for the path and directory the program files are to be
  266.    installed to. Select OK or press the RETURN key to accept the default
  267.    path and directory. If you wish to change this, type in a new path
  268.    and directory the program files should be installed to.
  269.  
  270. 4. Set-up will now copy the necessary files and create a new group
  271.    containing the Program icon.
  272.  
  273. 5. Once installation has been completed, Select OK or press the RETURN
  274.    key to continue.
  275.      
  276.  
  277.    - To run SCHEDULE minimized, from program manager select the 
  278.      SCHEDULER icon by clicking on it once, then Select the properties
  279.      option through the File-Menu and click the small box with the 
  280.      caption to the right "Run minimized" to add a check (X) within 
  281.      it. Click the OK button to continue.
  282.  
  283.    - If this is an evaluation copy you have installed, you will have
  284.      to edit the .INI file, using a standard text editor to
  285.      change default program environment parameters. 
  286.  
  287.    - If you have installed a full version of SCANNER, you can simply
  288.      select the SCANEDIT icon, make changes and click exit when done.
  289.  
  290.  
  291. ** Implementation:
  292.  
  293. - The program commences by reading parameters settings from the
  294.   specified .INI file. If the no INI file is specified, the default
  295.   file in the installation directory is used.
  296.  
  297. - If the scan directory named in the .INI file is not found, a
  298.   warning message will be displayed each time the scan occurs, the
  299.   program will still continue to run, but no files will be found.
  300.  
  301. - If the program is unable to find/create the log file name given in
  302.   the "LogPath" directory, a warning message will be displayed, the
  303.   program will continue to run with the logging function disabled.
  304.  
  305. - Every second, the program will check to see whether it is time for
  306.   the next scan. At the due scan time, a check will be made for a
  307.   file matching the given mask in the given directory. If found, it
  308.   will be renamed according to the rules set by the parameters in the
  309.   .INI file.
  310.  
  311. - When renaming to the "NewName" parameter, a warning will be
  312.   displayed if a file of "NewName" value already exists, the rename
  313.   will not be performed.
  314.  
  315. - When renaming to a date/sequence number parameter, at the start of
  316.   each run the program will attempt to start with sequence number 1.
  317.   If files with the desired date/sequence number already exist, they
  318.   will be skipped until a free sequence number can be found. If no
  319.   free sequence number is found, a warning will be displayed and the
  320.   rename will not be performed. When the last available sequence number
  321.   has been used on a particular day, the program will start again at 
  322.   sequence 1. When the date changes, the program starts renaming with
  323.   the new date and sequence number, starting from 1.
  324.  
  325. - When a successful rename is performed, a line will be written to
  326.   the "LogPath" log file giving the file name, time, date and file
  327.   size.
  328.  
  329.  
  330. ** Although the program is designed to run minimised, if maximised it
  331.    will display the following status information.
  332.  
  333. Scanning for file:       - mask to scan for.
  334. In directory:            - directory to check for files.
  335. Last file:               - last name an incoming file was renamed
  336.                to.
  337. Received on:             - date and time the last rename occurred.
  338. Total files:             - the number of renames (or attempts) since the
  339.                program has been running.
  340.  
  341.  
  342. ** If the parameters are changed in the .INI file, the program must be
  343.    reloaded before the new settings take effect.
  344.  
  345.  
  346. -------------------------------------------------------------------
  347.  
  348. KNOWLEDGE SOLUTIONS LTD
  349.  
  350. If you require any additional information regarding SCHEDULE
  351. or need to place an order then please do not hesitate 
  352. to Call our UK Sales Office +44 (0) 181 566-9106 or E-Mail 
  353. Sales@netbureau.com or Fax +44 (0) 181 991-2653 or sign-on
  354. to our on-line service: +44 (0) 181 566-9118 (8/N/1) or Post
  355. your enquires or orders to the address below.
  356.  
  357. CHEQUE, VISA and ACCESS excepted.
  358.  
  359.  KNOWLEDGE SOLUTIONS LTD, RESEARCH HOUSE, FRASER ROAD, 
  360.  PERIVALE, MIDDX, UB6 7AQ, ENGLAND.
  361. -------------------------------------------------------------------
  362.  
  363.  
  364.  
  365.